According to Neff, for the hole cut out of the worktop, the minimum front and back distances from hob to back wall and front edge to counter are 50mm (front) and 55 mm. robertpstubbs Screwfix Select. Should the product require repair please contact our repair service to arrange collection and repair. If it needs hardwiring, get a dual appliance connector plate. A dedicated 32A cable runs from the CU to the oven. 5KW electric hob. He has backed ou and need to revert to NAPIT for advice. Screwfix Select. £10. com. 56 Amps total, with diversity. Where two stationary cooking appliances are installed in one room, one. White PVC Sheathed Cable. 5 +21. Delivery. Repair Service Action. Product Width. Available in styles & finishes to suit your kitchen. €91. Time 3095Y White 5-Core 0. Insttead the app;liance has a terminal connection plate on the back accessed under a cover. Click & Collect. Just twice in the last few days. 375. Sepparate Ovens (in general) can be run off a socket outlet, and indeed come with a 3 pin plug attached. Buy online and collect in store in as little as 1 minute. Induction Hob. 6 x 49. Bosch PCP6A6B90 58cm Gas Hob - Black. Order Cooke & Lewis GASUIT4 Gas Hob Stainless Steel 83mm x 580mm at Screwfix. the gas connection to the free standing cooker is by means of a flexible rubber pipe with bayonet fitting. Please do not return to store. Induction Hob says its depth is 44mm. It provides a protective barrier between the hob cabinet and the underside of the hob. 590 mm. 2A) Applying diversity gives 100% of the first 10A plus 30% of the remaining 35. View all: MK Flex Outlets. FREE next day delivery available, free collection in 1 minute. Typically used for supplying internal power to appliances such as electric showers, cooker and induction hobs, 6mm twin and eath cable is flat for easier installation into plaster. Hans_25 Screwfix Select. Add to basket. Basket. The other question i have concerns the hob. When I switch the hob back on at the fuse board, it's ok again, but trips at a random time, even when not in use. get it done by a corgi reg installer. lee49 New Member. The radial circuit already exists and the cable used is the correct guage for the load. It has a flex fitted with 2 blue wires connected together, 2 yellow and green wires connected together and 1 brown and 1 black wire connected together. 8kw. e. My question is, what is an omnipolar cut. Bob Rathbone Screwfix Select. Brown, Black, Blue, Grey & Green/Yellow Cores. 4 kw. Screwfix Community Forum. Buy any 10+ Save 10% - View Offer. 5-amp electrical outlet. Requires 25mm Back Box. Screwed Faceplate. 6mm cable would give 32A (7. All that said there are practicalities that come into. UK call centre ready for your call. Order online at Screwfix. 19 Inc Vat. Timer. 85 kg. I want to run the cable from the kitchen to the cupboard where the consumer unit is myself and then get the electrician to install the ovens and hob at one end and do the work on the consumer unit (we may need a new consumer unit but the electrician sill sort all that out). Alternatively you could take a 13A fused spur off the closest socket and connect the hob. Screwfix Community Forum. 00 Save £60. My neighbour has asked a qualified gas engineer to provide a gas connection point in her kitchen for a new gas hob. It has starting getting small cracks in the worktop around the edge of the hob next to the ring I use the most. 2kW (44A) 10mm cable. One other thing is that the hob as well as other appliances connect to a 80amp mcb as we had the kitchen redone a few years ago. those are the cables supplied. MGW Screwfix Select. 95 Inc Vat. #8. I have a 6mm cable from my cu to a cooker connecter box via a 45 dp switch which protected by 30A fuse, I want to wiring in a 5. Wife's son as give me an induction hob he as had given, to install. Safety lock feature ensures controls are not operated by accident. So if you were to run the induction hob with all 'burners' on and the oven in pyrolytic mode through the existing oven circuit then the 32 amp MCB would trip. (100) £. Requires 25mm Back Box. Looking at the oven although its 880 height (including legs) the top is basically the controls with beding that 40mm lower. The hob is sat right on top of the ovens and there is a small gap between the hob and the worktop at the front (see attached pics) Now its all. The technical data states, conductors (number & size)3 x 2. I don't think so, the hob is currently gas and the oven electric just plugged in to a double socket at the back. The oven is rated at 16 amp. £13. To do this drill a small hole just big enough for the flex in the back of the side panel, feed the flex through, fit a plug. 6. I purchased an electric built under double oven, the first couple wouldn't fit but now I have one with a slant at the back to allow for the gas pipe on the back of wall. Wiring a 7. Add to wishlist. We have 6mm T&E from the CU to a hob isolator switch on the kitchen wall. Conventional single electric oven with hard wired cable connection, twin grill and double-glazed door. The old units are both wired into a CCU, hob - 6mm cable, oven 2. kitchen appliances. DIYDave. Quick installation via an existing socket or alternatively can be hard wired by a qualified electrician for full functionality. britishblue New Member. ★★★★★ Read 3 reviews. You need to read it properly: The minimum distance between the supporting surface for the cooking equipment on the hob and the lowest part of the range hood must be not less than 55cm from electric cookers and 70cm from gas or mixed cookers. 00 Save £10. Features 4 functions including grilling and plate warming. (Gas CH/HW still needs electricity. 07kw). pj123, May 18, 2014. Safety Gas Cut-Out. Next. If the hob is installed over a compact oven, there must be a. the thicker one is the hob. Timer. One of the biggest advantages is the ease of cleaning as you just have a sheet of glass to wipe over, with no burnt on food. Requires 25mm Back Box. , Mar 15, 2018. But if i turn the isolator switch on with the hob disconnected its fine. Perhaps I should persuade the my mother-in-law to get a decent electric hob ! Sam, Jun 16, 2006 #5. 1KW/32amp. 5mm cable, supplied from a 45A cooker switch, which is supplied via 6mm cable, protected by a 40A MCB in the CU. com. However, he seems to have second throughts. I have a electric hob (input 5500W) which my electrician has connected to the cooker switch using a 6mm T+E cable. The technical data states, conductors (number & size)3 x 2. Neff T58FD20X0 80cm Induction Hob - Black. That isn't the process. I have searched the internet and not found an answer that is specific to gas hob and electric oven. It's a heavy base wok so distributes heat evenly unlike a thin carbon steel wok. 5kw) and electric oven (rated at 2. com. Basically a school cookery room requires 10 x electric hobs rated at 7kW each and 10 x electric ovens rated at 3 kW each . 47 x 30 % =10. Dr Bodgit, Oct 24, 2017. The thread also includes links to products and specifications of different hobs. 2 year guarantee. The oven goes on a 13A plug, so that's straightforward. The work top is 600mm. Screwfix Community Forum. 4. Raised Square Profile. Bazza, Feb 4, 2022. 7kW and the ovens 2. I will follow your advice to get a 13amp max oven and just have the oven and GAS Hob connected. Garry Ingham said:. 49 Inc Vat. 4 Cooking Functions. Most are under 3 kW (approx rating for a 13A plug) 4 ring hob, probably not; unless it's a 2 ring 'domino hob' pulling less than 3 kW. I usually paint the exposed chipboard edge with waterproof PVA (several coats), but you could use yacht varnish. . Mr Milliamp Member. British General 900 Series 45A 2-Gang DP Cooker Switch & 13A DP Switched Socket White (56392) (39) compare. All ovens are the same width so there's no issue there. Discussion in 'Electricians' Talk' started by jasondo23, Dec 6, 2009. 60a - 10a = 35. Both the old and new hob are rated at 5. Buy Bathrooms & Kitchens at Screwfix. electric oven hob; Page 2 of 2 < Prev 1 2. P=Power, V=Volts, and I = amps P = V x I P/V = I 8800/240 = 36. 590 mm. 75mm² Heat Resistant Cable 50m Drum (20292) (15) compare. Currently in my kitchen we have a range cooker with an electric oven and a gas hob. Buy Hob Appliances at Screwfix. Child /. 5mm or equiv cable length max 2m The hob has connectors for a cable but no supplied cable or plug The oven manual states 220-240v cable type: HO5VV-F 3X 1. From the photos, it’s pretty clear that the glass cooktop has detached from the frame that holds it into the recess. Yes, all kitchen sockets are connected to the same 32-amp MCB. #2. ElecCEng, May 29,. You need to seal the cut edge of the chipboard, otherwise if water gets under the hob, the chipboard will absorb it and swell up and ruin your worktop. £8. Done right it could look quite good. That removes the need to chop off the plug. I already have an electric oven and gas hob fitted. Pay your way. £72. Sign in / Register. Offer - 20% off this when you spend £1500+ on kitchen worktops, cabinets and doors. 1 2. Click & Collect. Repair Service Action. Raised Square Profile. If your induction hob comes with a factory fitted 13A UK plug, then you can plug it in to the standard UK socket using its factory fitted plug. So if it's OK to run all three off the same supply via the 45a switch then it would make the job a lot easier and cheaper! Thanks again. #4. I have a new 13 amp oven coming which will have a three pin plug & a. Screwed Faceplate. Free next day delivery available. ProDave New Member. could it be wrong MCB rating, faulty MCB? any advice much appreciated cheers, SamDepends on the type of clips/clamps they send with the hob then. Add to wishlist. stateit, Jan 11, 2014. Convenience: These hobs are designed for swift and trouble-free setup, making them. For a electric hob, the minimum space above it is 600mm. Those who increase the cable size to 10mm2 are unfamiliar with domestic cooker circuits and are wasting money; it wont achieve any benefit whatsoever. Great deals on Electric Hobs. Raised Square Profile. Discussion in ' Plumbers' Talk ' started by Peter160482, Mar 14, 2021 . 5MM2. Raised Slim Profile. Delivered by our approved supplier, Find out more. 5mm2 ring which is protected by a 32A MCB. If not, then just relieve the underside of the worktop by 10mm to allow the clips to fit. UK call centre ready for your call 24/7. Delivered by our approved supplier, Find out more. So for a new cooker circuit, will they install a double socket under the worktop to plug in the electric oven and electric hob, then a single fused switch above worktop to control both at the top like this?Chris Sanderson New Member. Control Type: Touch. Requires 47mm Back Box. I have a Howdens kitchen that is in the process of being built, and there is an electric hob in the worktop which seems to only be installed by placing it into the worktop with sponge strips. 99 Inc Vat. Dan dan the man Active Member. Several options available. You may find that they will clamp down on 50mm tops. 5 mm cables or 3x2. follow the useless instructions, without any justification, and ignore my question about the unsuitability of the supplied sealing strip. The Scolmore one in your first link has two cable outlets. 4 x Plates. I have an existing single one electric oven & standard electric hob, both hardwired into a flush dual outlet plate (one gang). The hob can run on 6mm and even 2. Large Capacity Easy to Wire Terminals. Buy any 10+ Save 10% - View Offer. The oven circuit is fused at 32A. If it works with L1 and L2 together, with the marking of “25A” usually meaning per phase, it is going to give 50A on the neutral at full load. The old hob was fed from a 4mm cable. All on a 40amp breaker or would it be best to de-rate down to. 25. Don't be tempted to use masses a small bead. Cooker is reactivated by resetting the system once the cause of the alert has been investigated and controlled. £72. 99 More info. Touch-Dry in 1-2 Hours. com. That isn't the process. 5mm2 T&E from jb to double socket. Also the supplied cable for the oven seems a bit lightweight to put into a connection plate. Choose options. 5kw for the hob, a total of 10kW. Plug In and Go. Buy any 10+ Save 10% - View Offer. CDA 30cm 2 Zone Domino Ceramic Hob. Bob Rathbone Screwfix Select. Order Cooke & Lewis GASUIT4 Gas Hob Stainless Steel 83mm x 580mm at Screwfix. Now obviously this is not good and ive recommended a different layout of the kitchen and to try get the hob above some cupboards where. Timer. You could always think of another way though. However, the oven will still not fit because of a pipe coming down from the hob itself. Raised Rounded Profile. British General 900 Series 10A 1-Gang 3-Pole Fan Isolator Switch White (69862) (42) compare. Free next day delivery available. You need to fuse the cooker hood, and ideally the oven down after the cooker switch. It shows 2 live terminals. UK call centre ready for your call 24/7. We delve into the differences between ceramic, solid plate and. Cable will be Twin 6mm + 2. The existing socket is most likely on 2. 3. British General 900 Series 10A 1-Gang 3-Pole Fan Isolator Switch White (69862) (42) compare. Its cooking zones and controls are invisible until your fingertips bring them to life. It appears the only the (steel) saucepans on top get heated so the only heat coming downwards would be limited to the temperature of the saucepan (around 100 degC) as there is no 2. Samsung NZ84F7NC6AB_BK 80cm Electric Hob - Black (2) £ 818. There needs to be a gap of at least 65cm between your hob and the cooker hood or ceiling. If the oven is designed to be plugged in via a 13A socket then it will be supplied with a factory fitted flex and moulded 3 pin plug. 04 amps. My electric Zanussi hob has recently started tripping the mains electric. If it is 7000W, this would be 29A at 240V, so 4mm2 flex (which could theoretically handle about 32A) should be OK. Delivery Next day available. All we need to know is what the rating for the oven is! Bazza, Mar 31, 2021. Add to basket. However if the hob is a few years old, the use silicon. hob spec: -PVC insulated connection cables type ho5 vv-f or ho5v2v2-f with yellow-and-green protective conductor, or other equivalent superior cables. an electric hob and a built in electric oven (Smeg) in a domestic kitchen. £ 3. The distance between the top of the hob and the top of the. 7 kW into a single ring, where the 13A socket can only. Old hob specs from data sheet below. I think I'm going to use silicone. 5MM2. W x H x D: 260 x 90 x 7mm. Need Help. You may be able to fit 2x 16mm end panels in the gaps if your opening is 632mm. Screwfix Community Forum. If the button ain't movin', then try gently pulling it upwards too. Each cooking plate has a separate neon indicator and the base of the hob. Plug In and Go. Home Forums > Screwfix Community Forum > Electricians' Talk > Help Fitting Electric Hob! Discussion in 'Electricians' Talk' started by dazz25, May 25, 2007. Repair Service Action. I'm currently changing my hob for a new one. That means the top of the pan supports not the worktop. 00mm. Boost function. Cooke & Lewis CLCER30A Ceramic Hob Black 60mm x 290mm (777FK) compare. hob is 6kw - 26 amp cooker 2. Several light coats will give a better finish than a single heavy coat. UK call centre ready for your call 24/7. #26. Having ploughed through loads of specification on AO. Warranty: 2 year warranty. I lifted the old hob to see where the wire goes. electric hob trips whenever either of the two bigger plates are switched on. I have a new electric hob , the earth terminal is marked but the other 2 are not so does it matter which goes to the live and. Scolmore is a brand with a very good reputation, and the link you give has a price for it that none of the wholesalers I have accounts with could. 3 kw 10 ampI currently have an Electric oven on a cooker circuit with a 32 AMP MCB and a Gas Hob on the Kitchen circuit with a 32 AMP MCB. Screwfix Community Forum. Bazza Screwfix Select. Hello, I am having a new electric single oven and induction hob delivered. It will most likely have a 45A switch on it. That way you are not only testing it for functionality (like it heats up) but also the RCD will trip idf there is an earth leakage fault. 4. 49 Inc Vat. So I am wondering does diversity apply to the combined total wattage of both the appliances or just the oven. 5KW electric hob. 5kW. Order Cooke & Lewis CSB60A Built- In Single Electric Oven Stainless Steel 595mm x 595mm at Screwfix. British General 900 Series 13A 2-Gang SP Switched Plug Socket White 5 Pack (48563) (62) £13. Prysmian 6943X Black 3-Core 10mm² Armoured Cable 25m Drum (21963) (6) compare. #26. Discussion in 'Electricians' Talk' started by SpuddyMcFuddy, Nov 14, 2017. 6a = 24. Is that correct?. If so, spray - ideally with a straw - a small amount on that shaft and press the button repeatedly downwards. 29 Inc Vat. s black glass design with an easy clean surface for quick maintenance, a timer for accurate cooking, auto safety switch off and a safety key lock to prevent accidents and overspills. I originally thought this meant to use either 5 or 3 cables. Under worktop oven. One of the biggest advantages is the ease of cleaning as you just have a sheet of glass to wipe over, with no burnt on food. 00. Gas or Electric hob. Before I contact the manufacturers I'd thought I'd seek your help. The cooker is rated at 10. 5mm cable, but you need to change some jump connections on the unit itself depending on the power source; But it will not work at full capacity which defeats the. It separates your cabinet storage space from the cooktop. 4. 47 amps. Heat-Resistant. Transform the kitchen and turn cooking. There most certainly is regarding gas hobs, unless the sink is stainless steel or vitreous ceramic, it has to be a minimum of 150mm from the edge of the sink. Repair Service Contact. 3A. I hope this the right thread. 29 Inc Vat. 1/5. Cooke & Lewis CLIND60 Induction Hob Black 68mm x 590mm (852FH) (13) compare. British General 900 Series 45A 1-Gang DP Cooker Switch White with Neon (67918) (26) £7. Cooke & Lewis CGSBCER60 560mm Ceramic Hob, Hood & Splashback Black (145KH) compare. Requires 25mm Back Box. Hello. This is why 3kW immersion heaters are on separate circuits. 68 per month*. com. Write a review. 1 x 59 x 52 cm (H x W x D) 4 zones. Discussion in 'Electricians' Talk' started by mb, Jun 9, 2004.